ATTENZIONE: la sezione Public mostra solo parte degli articoli disponibili, eseguire il login come cliente per accedere a tutti i suggerimenti e soluzioni.
ATTENTION: the Public section shows only part of the available articles, log in as a customer to access all the suggestions and solutions.
ACHTUNG: der frei zugängliche Bereich zeigt nur einen Teil der verfügbaren Artikel. Loggen Sie sich als Kunde ein, um alle Vorschläge und Lösungen anzuzeigen.
ATTENTION: la section Public n’affiche qu’une partie des articles disponibles, connectez-vous en tant que client pour accéder à toutes les suggestions et solutions.
ATENCIÓN: la sección Pública muestra solo una parte de los artículos disponibles, inicie sesión como cliente para acceder a todas las sugerencias y soluciones.
ATENÇÃO: a seção Pública mostra apenas uma parte dos artigos disponíveis, faça o login como cliente para acessar todas as sugestões e soluções.


LOGIN
[HOW TO] My Genius - Recovery 0x0266/0x0366 (Client side)
Creation Time:
09 aprile 2024
Last Update Time:
03 luglio 2024
Article Level:
Public
The MyGenius tool went in a RECOVERY state (0x0266/0x0366) after the last writing performed failed to be completed.

The recovery state 0x0266 occurs when the MyGenius tool failed to correctly complete the vehicle writing.
The recovery state 0x0366 occurs when the MyGenius tool failed to complete the vehicle writing BUT managed to complete it at least once.

For both this recovery states, follow the instructions below:

1. First, you must try to perform a new write of the file that failed previously by following the instructions shown on screen by the My Genius tool.

2. If the writing operation fails again, exit from the recovery state by pressing the 'CANC' button on the MyGenius tool and select 'WORK --> WRITING --> ORIGINAL' to restore the vehicle to its original state. Afterwards, contact your Master to request a new MOD file to write.

3. If you are unable to restore the vehicle to its original state, contact your Master, extract the LOG files of the last writing attempts as following https://reserved.dimsport.com/kb/article.aspx?id=1746, send them together with the original ID/reading and wait for instructions.

4. ONLY if requested by the Master, connect the MyGenius tool to the PC, perform a 'FORCED RESET' request by clicking on 'File (1) --> Forced reset / Brand change request (2)' from the MyGenius Client software and follow the next instructions

MYGENIUS CLIENT:

 

MYGENIUS CLIENT V2:


N.B. Wait for confirmation by the Master and perform the required mandatory update with MyGenius Client software.
When finished, read the vehicle again and wait for your Master to send you the new MOD files to be written.